Design Criteria
SCON Standard designed in accordance with BSS 110 : 1997 and based on the following types of loading condition:
Type 1 : UDL of 10kN/m2 behind the wall
Type 2 : Surcharge of 600mm at the back of the wall (see figure)
SCON U-Drain available in Standard Sizes
-
Standard Sizes:
- 600mm (W) x 600mm (H) to 1800mm (W) x 1800mm (H)
Design Criteria
SCON Standard designed in accordance with BSS 110 : 1997 and based on the following types of loading condition:
Type 1 : UDL of 10kN/m2 behind the wall
Type 2 : Surcharge of 600mm at the back of the wall (see figure)
- Minimum cover Standard = 25mm
- Concrete grade shall be 30N/mm2 to 40N/mm2
- Bulk density of soil backfill to be 19kN/m3
- Angle of internal friction of soil back fill to be 30°