Design Criteria

SCON
Standard designed in accordance with BSS 110 : 1997 and based on the following types of loading condition: 

Type 1 : UDL of 10kN/m2 behind the wall
Type 2 : Surcharge of 600mm at the back of the wall (see figure) 
  • Minimum cover Standard = 25mm
  • Concrete grade shall be 30N/mm2 to 40N/mm2
  • Bulk density of soil backfill to be 19kN/m3
  • Angle of internal friction of soil back fill to be 30° 